Product Details:
Enclosure Type | IP20 |
Made in | Japan |
Security | Password Protection |
Hp | 18 |
Ambient temperature | Opening: -10 to +45 DegreeC |
1) Carrier frequency -: Setting range: 5 to 16kHz Note) The carrier frequency may drop automatically according to the ambient temperature or output current to protect the inverter. (The automatic decrease stop function is provided.)
2) Maximum speed -: It is 120Hz in inverter output frequency conversion. (2-pole: 7200r/min, 4-pole: 3600r/min, 6-pole: 2400r/min) PG frequency: 100kHz or less
3) Control range -: It is 0 to 120Hz in inverter output frequency conversion. (4-pole:0 to 3600r/min)
4) Control response-: 100Hz (Max)
5) Control accuracy -: Analog setting: ±0.2% or less at the maximum speed (25±10°C) Multistep speed and communication settings: ±0.01% or less at the maximum speed (-10 to +45℃)
6) Frequency setting resolution -: Analog setting: 1/1000 at the maximum speed Multistep speed setting : It is 0.01Hz(99.99Hz or less), 0.1Hz(100.0 to 120.0Hz) in inverter output frequency conversion. Communication: 1/20000 at the maximum or 0.1Hz(fixation) in inverter output frequency conversion.
7) Speed setting -: Multistep speed: External signal (Digital input) Combination of 3 points (8 step) Analog signal:0 to ±10V Multi-function keypad (Option):It is possible to set with and keys by a remotely/local change. Communication: RS485
8) S-curve acceleration/ deceleration setting -: Individual settings of each point of start, acceleration completion, deceleration beginning, and stop. (10 step) Setting range:0 to 50%
9) Sequence function -: Forced stop, The range of the S-curve, Acceleration and deceleration time, Multistep speed command setting simultaneously, Operation Command Agreement Timer, Multistep Speed Command Agreement Timer, Normal or negative logic selected function of digital input, Normal or negative logic selected function of digital output, Soft starting, Stop frequency continuance, Acceleration and deceleration operation function cancellation
10) Control function- : Torque control, ASR feedforward compensation, Vibration control observer, ASR parameter change, Digita
11) Special function -: Password, Unbalanced load compensation, Creepless operation, Battery operation
`12) Function for Synchronous Motor -Pole position offset tuning
`13) Installation location -: Shall be free from corrosive gasses, flammable gasses, oil mist, dust, and direct sunlight (Pollution degree 2(IEC60664-1)). Indoor use only
14) Ambient temperature -: Opening:-10 to +45°C
15) Altitud -: 1000m or less
16) Vibration -: 3mm : 2 to less than 9Hz 9.8m/s2 : 9 to less than 20Hz 2m/s2 : 20 to less than 55Hz 1m/s2 : 55 to less than 200H
17) Storage -: mb. Temp.-25 to +65℃ Amb. Humidity 5 to 95%RH (no condensation)